NPDES ID: MO0121274
D — SNC: Discharge monitoring report not received
The facility didn't submit its required discharge monitoring report.
This quarter: 1 effluent violation, 1 compliance schedule violation, 2 reporting violations.
Violations
June 30, 2026
E. coli
57% over limit
Discharged 323 MPN/100mL against a permitted limit of 206 MPN/100mL (30DA GM)
DMR, Limited - Numeric Violation
March 31, 2026
Nitrogen, ammonia total [as N]
131% over limit
Discharged 15.5 mg/L against a permitted limit of 6.7 mg/L (DAILY MX)
DMR, Limited - Numeric Violation
Nitrogen, ammonia total [as N]
434% over limit
Discharged 15.5 mg/L against a permitted limit of 2.9 mg/L (MO AVG)
DMR, Limited - Numeric Violation
BOD, 5-day, 20 deg. C
0% over limit
Discharged 0 mg/L against a permitted limit of 0 mg/L (MO AVG)
DMR, Monitor Only - Overdue
Solids, total suspended
0% over limit
Discharged 0 mg/L against a permitted limit of 0 mg/L (MO AVG)
DMR, Monitor Only - Overdue
pH
0% over limit
Discharged 9.13 SU against a permitted limit of 9 SU (MAXIMUM)
DMR, Limited - Numeric Violation
First flagged
April 14, 2026 (5 months ago)
Last confirmed
September 15, 2026 (4 days ago)