O'NEILL WASTEWATER TREATMENT FACILITY

NPDES ID: NE0049051

D — SNC: Discharge monitoring report not received

The facility didn't submit its required discharge monitoring report.

This quarter: 1 effluent violation.

Violations

May 31, 2026

E. coli, MTEC-MF

87% over limit

Discharged 236 MPN/100mL against a permitted limit of 126 MPN/100mL (MO GEO)

DMR, Limited - Numeric Violation

February 28, 2026

Nitrogen, ammonia total [as N]

108% over limit

Discharged 18.5 mg/L against a permitted limit of 8.88 mg/L (MO AVG)

DMR, Limited - Numeric Violation

Nitrogen, ammonia total [as N]

73% over limit

Discharged 21.53 kg/d against a permitted limit of 12.44 kg/d (MO AVG)

DMR, Limited - Numeric Violation

December 31, 2025

Solids, total suspended

0% over limit

Discharged 0 mg/L against a permitted limit of 30 mg/L (MO AVG)

DMR, Limited - Overdue

Flow, in conduit or thru treatment plant

0% over limit

Discharged 0 MGD against a permitted limit of 0 MGD (DAILY MX)

DMR, Monitor Only - Overdue

Temperature, water deg. fahrenheit

0% over limit

Discharged 0 deg F against a permitted limit of 0 deg F (DAILY MX)

DMR, Monitor Only - Overdue

First flagged

April 14, 2026 (5 months ago)

Last confirmed

September 15, 2026 (5 days ago)